background image

5. Remove the insulation cover from the suction accumulator/drier.

6. Remove the A/C accumulator mounting bracket from the suction accumulator/drier.

INSTALLATION

1. Follow the removal procedure in reverse order.

-

Service the replacement suction accumulator/drier with the proper amount of PAG refrigerant compressor oil F7AZ-19589-DA or Motorcraft
YN-12c or equivalent meeting Ford specification WSH-M1C231-B.

-

Lubricate the O-ring seal with PAG refrigerant compressor oil F7AZ-19589-DA or Motorcraft YN-12c meeting Ford specification
WSH-M1C231-B.

CAUTION:  To prevent damage to the fitting and the tube, use a backup wrench when installing the suction accumulator/drier.