Coupler HVAC: Description and Operation
Peanut Fitting

The A/C condenser core uses the peanut-shaped refrigerant fittings instead of spring lock couplings.

-

The male and female blocks of the peanut fitting are retained with a nut.

-

An O-ring seal is installed around the tube on the male block.

-

The female block is welded to the tube and is not adjustable.

-

Support the female fitting with a wrench to prevent twisting of the tubes.

-

The male block will pivot around the tube to allow for alignment with the female block during assembly.

-

When properly assembled the male and female fittings should be flush.