lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Peanut Fitting|Page 6639 > < Peanut Fitting|Page 6636
Page 1
background image

Coupler HVAC: Service and Repair
Peanut Fitting

DISCONNECT

1. Remove the nut from the peanut fitting.

CAUTION:  Support the female fitting with a wrench to prevent the tubes from twisting.

2. Pull the peanut fitting apart.

3. Remove the O-ring seal with a non-metallic tool.

CAUTION:  Do not use metal tools to remove the O-ring seal. They can cause axial scratches across the O-ring seal groove resulting in 
refrigerant leaks.

CONNECT

1. Clean all dirt or foreign material from the fittings.

Peanut Fitting|Page 6639 > < Peanut Fitting|Page 6636