lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Lifter / Lash Adjuster, Valve|Service Precautions > < Cleaning|Page 2226
Page 1
background image

Lifter / Lash Adjuster: Specifications

Clearance to Bore

Standard ............................................................................................................................................................  0.018-0.069 mm (0.00071-0.00272 inch)
Service Limit .............................................................................................................................................................................  0.016 mm (0.00063 inch)

Diameter (STD) .....................................................................................................................................................  16.000-15.988 mm (0.6299-0.6294 inch)
Leakdown Rate *

Time ..............................................................................................................................................................................................................  5-25 seconds
Distance ...........................................................................................................................................................................................  1.6 mm (0.0630 inch)

With 222 Newtons (49.9 pounds) load and tappet filled with leak-down fluid.

Lifter / Lash Adjuster, Valve|Service Precautions > < Cleaning|Page 2226