lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Evaporator Core|Description and Operation|Page 8291 > < Evaporator Case|Specifications|Page 8287
Page 1
background image

Evaporator Core: Description and Operation

 

NOTE:  Whenever an A/C evaporator core is replaced, also replace the suction accumulator/drier.

The A/C evaporator core is the plate/fin-type with a unique refrigerant flow path.

^

A mixture of refrigerant and oil enters the bottom of the A/C evaporator core through the A/C evaporator core inlet tube and is routed so that it
flows through the partitioned first five and one half plate/fin sections.

^

The next five plate/fin sections are partitioned to force the refrigerant to flow toward the other end of the A/C evaporator core.

^

The refrigerant then continues over to the remaining six and one half plate/fin sections and then moves out of the A/C evaporator core through the
A/C evaporator core outlet tube.

^

This S-pass flow pattern accelerates the flow of refrigerant and oil through the A/C evaporator core.

Evaporator Core|Description and Operation|Page 8291 > < Evaporator Case|Specifications|Page 8287