Evaporator Core: Testing and Inspection

ON-VEHICLE LEAK TEST

If an A/C evaporator core or A/C condenser core is suspected of leaking, the leak must be verified prior to removing the component from the
vehicle. This leak test should be performed. DO NOT rely solely on the results of an electronic leak detector as chemicals other than R-134a will
activate the leak detector.

1. Verify that the manifold gauge set is capable of holding vacuum.

a. Connect the red and blue hoses together using a 1/4 inch flare coupling.
b. Connect the gauge set yellow hose to a known good vacuum pump.
c. Turn the vacuum pump on and open both gauge set valves.
d. Operate the vacuum pump for one minute and close both gauge set valves. The low-side gauge should indicate approximately 101 kPa (30

in-Hg) of vacuum.

e. Allow the gauge set, with vacuum applied, to set for at least 30 minutes.
f.

If the gauge reading drops during that time, the gauge set hose connections, gauges or valves are leaking and should be repaired before
proceeding with the leak test.

2. Discharge the A/C system.
3. Disconnect the suspect A/C evaporator core or A/C condenser core from the A/C system. DO NOT leak test an A/C evaporator core with the 

suction accumulator/drier attached to the core tubes. Refrigerant outgassing from oil and desiccant in the suction accumulator/drier will
indicate a false leak condition.

4. Clean the evaporator or condenser core tube fittings.

If the core tube fittings are the female spring lock design, check the inside of each fitting for scratches, corrosion or debris from deteriorated
O-rings. If scratches, corrosion or debris are found, the leak test results may not be accurate unless the fitting is properly cleaned as follows:
a. Remove any surface residue from the inside of the female spring lock coupling by polishing with 400-grit emery cloth or equivalent. Polish

the female surface by using a twisting motion so that any scratches made will not cross the O-ring sealing surface.

b. Perform additional polishing of surface using 600-grit emery cloth or equivalent.
c. All residue from the polishing operation should be removed from the fitting by wiping with a lint-free cloth.