lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 9973 > < Electronic Instrument Cluster Tone|Page 9970
Page 1
background image

Audible Warning Device: Initial Inspection and Diagnostic Overview

1. Verify the customer's concern by operating the warning chime system to duplicate the condition.
2. Inspect to determine if one of the following electrical concerns apply:

VISUAL INSPECTION CHART

Electrical
-

Check system fuses 15 (15A), 18 (10A). 9 (5A), 6 (10A), 4 (10A).

-

Check electrical connections for obvious damage, shorts, or opens.

3. If the inspection reveals obvious concerns that can be readily serviced, correct the concern before continuing with Inspection and Verification.
4. If the concern remains after the inspection, connect the Rotunda New Generation Star (NGS) Tester 007-00500 or equivalent to the data link

connector (DLC) located beneath the instrument panel to perform DATA LINK DIAGNOSTICS test. If the NGS responds with NO RESPONSE I
NOT EQUIPPED for the lighting control module(s), GO to Pinpoint Test A.  See: Pinpoint Tests/Test A : No Communication With Lighting
Control Module
If the DATA LINK DIAGNOSTICS test is passed for the lighting control module, retrieve continuous DTCs and execute Self Test Diagnostics for
the lighting control module to retrieve current DTCs.

5. If self test is passed and no DTCs are retrieved, GO to the Symptom Chart to continue diagnostics.  See: Symptom Related Diagnostic Procedures
6. If DTCs are retrieved, GO to the Lighting Control Module (LCM) Diagnostic Trouble Code (DTC) Index to continue diagnostics.  See:

Component Tests and General Diagnostics/Lighting Control Module  Diagnostic Trouble Code  Index

7. If the lighting control module(s) cannot be accessed by the NGS, GO to Pinpoint Test A.  See: Pinpoint Tests/Test A : No Communication With

Lighting Control Module

Rotunda Service Bay Diagnostic System (SBDS (R)) 001-00001 may also be used to diagnose this system.

Initial Inspection and Diagnostic Overview|Page 9973 > < Electronic Instrument Cluster Tone|Page 9970