Voltage Regulator: Description and Operation

The voltage regulator:

-

Adjusts the generator field current to increase or decrease generator output current.

-

Sets the generator output voltage.

-

Turns the generator warning lamp ON when a problem is detected in the charging system or associated wiring.

The generator output voltage will vary with temperature. The output voltage is typically higher in the winter (cold) and lower in the summer (hot).

The voltage regulator will turn the indicator lamp ON for these conditions:

-

Ignition switch in the RUN position with the engine not running. This is the lamp prove-out (does not indicate a problem with the charging system
).

-

Open in the A circuit or S circuit.

-

Inoperative generator.

-

Generator output voltage too high.

If the indicator lamp stays ON with engine running, refer to Charging System, pinpoint test C.  See: Testing and Inspection/Pinpoint Tests/C: Charge
Lamp Stays On, Eng Running