Compressor/Pump Relay: Description and Operation

The relay is needed because the control module cannot directly provide the high current needed to run the compressor motor. It operates as follows:

^

The control module grounds Circuit 420 (DB/Y) to energize the relay coil.

^

When energized, the coil creates a magnetic field which closes the relay contacts, connecting Circuit 1053 (LB/PK) to Circuit 538 (GY/R).

^

High current then flows from battery to the compressor motor.