6. Install TR sensor on manual control lever and two shims, then loosely install bolts.
7. Position manual control lever in NEUTRAL.

NOTE:  PARK is the last detent when the manual control lever is full forward. Return two detents toward output shaft for NEUTRAL.

8. Insert Transmission Range (TR) Sensor (MLPS) Alignment Tool T93P-70010-A into slots. Align all three slots on TR sensor with three tabs on

tool.

9. Tighten TR sensor bolts to 7-10 Nm (62-88 inch lbs.).

10. Clean, inspect and install pan-to-case gasket and transmission pan. Tighten all bolts to 12-15 Nm (107-132 inch lbs.).

NOTE:  Transmission pan-to-case gasket is reuseable if not damaged.

11. Install transmission linkage to manual control lever.
12. Pour 4.7 liters (5 quarts) of Motorcraft MERCON Multi-Purpose (ATF) Transmission Fluid XT-2-QDX or equivalent MERCON approved fluid

into fluid filler tube. MERCON(R) automatic Transmission Fluid is being replaced by MERCON(R) V as a service fluid, as per TSB 06-14-4.

13. Reconnect battery ground cable.