Shift Solenoid: Description and Operation

Chart #701

SS-1 AND SS-2 

Two ON/OFF shift solenoids are used for electronic shift scheduling. One unit containing the two shift solenoids is located in the main control valve
body. The shift solenoids are two-way, normally closed style. Shift solenoids 

(SS-1) and (SS-2) provide gear selection of first through fourth gears by

controlling the pressure to the three shift valves. 

TORQUE CONVERTER CLUTCH SOLENOID 

The torque converter clutch solenoid is used to control the apply and release of the torque converter clutch. 

ELECTRONIC PRESSURE CONTROL (EPC) 

The EPC solenoid regulates transmission EPC pressure. EPC valve pressure is used to control line pressure and the 2-3 backout valve function.