Add the same amount plus the amount collected during refrigerant recovery.

Oil Injection Using a Dye/Lubricant Injector

NOTE:  If fluorescent leak detection dye is also to be added during A/C charging, the dye may be added to the dye/lubricant injector along with the 
refrigerant oil.

1. Evacuate the refrigerant system.
2. Assemble the dye/lubricant injector using the correct adapters to match the amount of refrigerant compressor oil to be injected.

3. Verify that all the valves on the dye/lubricant injector are closed.

4. Fill the dye/lubricant injector with the correct amount of new refrigerant compressor oil.
5. Install the dye/lubricant injector between the low-side service gauge port valve and the refrigerant service station or manifold gauge set.
6. Open all valves and charge the refrigerant system.