3 L4-2.3L (2004)
6. Identify and carefully cut Black, protective tube of airflow sensor harness using scissors.
7. Using 1/16" (1.7mm) wide pin extractor from Terminal repair kit, remove Black ground wire terminal from airflow sensor connector.
8. Cut off ground wire terminal at base with wire cutter.
9. Remove approximately 1/2" (10mm) of insulation from Black ground wire.