10. This step applies short cord PN - BNYP-67-SH0. Measure from end of short cord opposite terminal end and cut off 1-1/2" (40mm) of wire.
11. Remove approximately 1/2" (10mm) of insulation from new end of short cord.
12. Twist short cord harness wire and Black ground wire together then solder.
CAUTION:
- Follow all necessary precautions for safe soldering such as gloves, eye goggles, and respirator.
- Place protective cloth under harness to prevent damage from loose solder.