6. Insert the SST quick release connector into the fuel pipe until a click is heard.

7. Verify that the quick release connector is firmly connected by pulling it by hand.

8. Start the fuel pump using the following procedure. 

Using M-MDS

-

Connect the negative battery cable.  See: Starting and Charging/Battery/Service and Repair/Removal and Replacement

-

Connect the M-MDS to the DLC-2.

-

Using the simulation function "FP", start the fuel pump.  See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Scan Tool Testing and Procedures/On-Board Diagnostic Test

Without using M-MDS

-

Remove the fuel pump relay.

CAUTION:

-

Short the specified terminals because shorting the wrong terminal of the relay and fuse block may cause malfunctions.

-

Using a jumper wire, short fuel pump relay terminals C and D in the relay and fuse block.

-

Connect the negative battery cable and operate the fuel pump.

9. Operate the fuel pump for 10 s.

10. Measure the fuel line pressure. 

-

If not within the specification, inspect the following:

If it less than the specification:

-

Fuel pump unit

-

Fuel line for clogging or leakage

If it exceeds the specification:

Fuel Pressure|Specifications|Page 1740 > < Fuel Pressure|Specifications|Page 1738