3 L4-2.5L (2010)
Hazard Warning Switch: Testing and Inspection
HAZARD WARNING SWITCH INSPECTION
1. Disconnect the negative battery cable.
2. Remove the center panel. See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Removal and
Replacement/Center Panel Removal/Installation
3. Verify that the continuity between the hazard switch terminals is as indicated in the table.
-
If not as indicated in the table, replace the hazard warning switch.
4. Apply battery voltage to hazard switch terminal A, and connect terminal F to ground.
5. Verify that the LED illuminates.
-
If there is any malfunction, replace the hazard warning switch.