3 L4-2.5L (2010)
PCM terminals
-
2AA(+)-body ground(-)
Oscilloscope setting
-
0.5 V/DIV (Y), 2 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm up
Generator output voltage
PCM terminals
-
2AF(+)-body ground(-)
Oscilloscope setting
-
2 V/DIV (Y), 2 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm up
Fuel injection (#1, #2, #3, #4) control
PCM terminals
-
Fuel Injection No.1: 2BB(+)-body ground(-)
-
Fuel Injection No.2: 2BC(+)-body ground(-)
-
Fuel Injection No.3: 2BD(+)-body ground(-)
-
Fuel Injection No.4: 2AZ(+)-body ground(-)
Oscilloscope setting
-
10 V/DIV (Y), 25 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm up