3 L4-2.5L (2010)
-
TCM terminals
AC (+)-body GND (-)
-
Oscilloscope setting
1 V/DIV (Y), 2.5 ms/DIV (X), DC range
-
Test Condition
Vehicle speed at 30 km/h {19 mph}.
VSS
-
TCM terminals
Z (+)-body GND (-)
-
Oscilloscope setting
1 V/DIV (Y), 2.5 ms/DIV (X), DC range
-
Test Condition
Vehicle speed at 30 km/h {19 mph}.