3 L4-2.5L (2010)
Refrigerant Pressure Sensor / Switch: Testing and Inspection
Refrigerant Pressure Sensor Inspection - Manual Air Conditioner
REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]
1. Install the manifold gauge.
2. Verify the high-pressure side reading of the manifold gauge.
3. Measure the terminal voltage of the climate control unit.
-
1G,1H and 2J
4. Verify that below graph as measure the terminal voltage 2J.
5. Follow the climate control unit inspection when measure the other terminal voltage. See: Heating and Air Conditioning/Control Assembly/Testing
and Inspection/Component Tests and General Diagnostics/Climate Control Unit Inspection - Manual Air Conditioner
-
Terminal 1G: 1.0 V or less
-
Terminal 1H: Approx. 5 V (Ignition switch on)
-
If the each voltage is not normal, inspect the related wiring harness.
-
If there is any malfunction, replace the related wiring harness.
-
If wiring harness is normal, replace the refrigerant pressure sensor.