5 L4-2.3L (2007)
OCV signal
PCM terminals
-
2E (+)-body ground (-)
Oscilloscope setting
-
2 V/DIV (Y), 0.8 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm up
CMP signal
PCM terminals
-
2S (+)-body ground (-)
Oscilloscope setting
-
1 V/DIV (Y), 25 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm up
CKP signal
PCM terminals
-
2W (+)-body ground (-)
Oscilloscope setting
-
1 V/DIV (Y), 2.5 ms/DIV (X), DC range
Vehicle condition
-
Idle after warm up
Generator field coil control signal