Mazda Workshop Service and Repair Manuals

A/C - Stops Cooling After Long Drive When Hot/Humid|Page 399 > < A/C - Stops Cooling After Long Drive When Hot/Humid
Page 2
background image

The cause of the evaporator freeze-up is product variation of the evaporator temperature sensor and uneven airflow across the evaporator. To correct the
sensor, a short harness with a built-in resistor will need to be installed in series with evaporator temperature sensor circuit. This cord will correct it by
reducing the measured value 1°C (1.8°F). To correct the airflow, a cabin filter with a built-in diffuser will need to be installed in place of the current
filter.

Customers having this concern should have their vehicle repaired using the following repair procedure.

REPAIR PROCEDURE

1. Verify customer concern.

2. Record the customer's radio station presets.

3. Disconnect the negative battery for at least one minute.

4. Remove the side wall on the passenger side foot well.

5. Remove the Passenger Juction Box. Refer to MS3 online instructions or Workshop Manual section 09-40 PASSENGER JUNCTION BOX (PJB)
REMOVAL/INSTALLATION.

NOTE:

PJB module configuration does not need to be performed since the same module will be used.

6. Remove the metal bracket.

7. Disconnect the connector from the evaporator temperature sensor connector.

A/C - Stops Cooling After Long Drive When Hot/Humid|Page 399 > < A/C - Stops Cooling After Long Drive When Hot/Humid