5 L4-2.3L (2007)
Starter Relay: Testing and Inspection
RELAY INSPECTION
Relay Type
Type A
1. Verify the continuity between the relay terminals.
-
If not as indicated in the table, replace the relay.
Starter Relay: Testing and Inspection
RELAY INSPECTION
Relay Type
Type A
1. Verify the continuity between the relay terminals.
-
If not as indicated in the table, replace the relay.