6 L4-2.5L (2010)
10. Stop the fuel pump using the following procedure.
Using M-MDS
-
Using the simulation function "FP", stop the fuel pump.
Without using M-MDS
-
Disconnect the negative battery cable to stop the fuel pump.
11. Measure the fuel hold pressure after 5 min.
-
If not within the specification, inspect the following:
-
Fuel line leakage
Fuel hold pressure
-
200 kPa {2.04 kgf/cm2, 29.1 psi} or more
12. Complete the "BEFORE SERVICE PRECAUTION". See: Powertrain Management/Fuel Delivery and Air Induction/Service Precautions/Vehicle
Damage Warnings/Before Service Precaution
13. Disconnect the SST.
14. Connect the quick release connector. See: Powertrain Management/Fuel Delivery and Air Induction/Fuel Line Coupler/Service and Repair/Quick
Release Connector Removal/Installation
15. Complete the "AFTER SERVICE PRECAUTION". See: Powertrain Management/Fuel Delivery and Air Induction/Service Precautions/Vehicle
Damage Warnings/After Service Precaution