6 V6-3.0L (2007)
Radiator Cooling Fan Motor: Testing and Inspection
COOLING FAN MOTOR INSPECTION [L3, AJ]
L3
1. Verify that the battery is fully charged.
2. Connect the battery positive voltage and an ammeter to the fan motor connector.
3. Verify that the fan motor operates smoothly at the standard current draw.
^
If not within the specification, replace the fan motor.
Standard current [12 V]
8.5 - 11.5 (A)
High (Cooling fan motor No.1 and No.2)
Middle (Cooling fan motor No.2)
Low (Cooling fan motor No.1 and No.2)
AJ
1. Verify that the battery is fully charged.
2. Disconnect the fan control module connector (3 terminals).
3. Connect the positive battery voltage and an ammeter to the fan control module connector on fan motor side. (2 terminals)
4. Verify that the fan motor operates smoothly at the standard current draw.
^
If not within the specification, replace the fan motor.
Standard current [12 V]
11.8 - 14.8 (A)