6 V6-3.0L (2007)
Air Door Actuator / Motor: Testing and Inspection
Airflow Mode Actuator
AIRFLOW MODE ACTUATOR INSPECTION [L3, AJ]
Full-auto Air Conditioner
1. Connect battery positive voltage to terminal E or F and ground to terminal F or E of the airflow mode actuator.
2. Verify that the airflow mode actuator operates as shown above.
-
If not as specified, replace the airflow mode actuator.
3. Verify that the resistance between the terminals of the airflow mode actuator is as shown in the graph.
-
If not as specified, replace the airflow mode actuator.
Manual Air Conditioner
Operating inspection
1. Turn the fan switch to OFF
2. Turn the mode dial to VENT.
3. Turn the ignition switch to ON position. (engine ON)
4. Turn the fan switch 4th position.
5. Turn the mode dial from VENT to DEFROSTER.