2. Inspect the following wiring harness for open or short (Continuity check). 

Open circuit 

-

If there is no continuity, the circuit is open. Repair or replace the harness.
-

EGR valve terminal E (harness-side) and PCM terminal 12

-

EGR valve terminal A (harness-side) and PCM terminal 72

-

EGR valve terminal B (harness-side) and PCM terminal 46

-

EGR valve terminal F (harness-side) and PCM terminal 56

-

EGR valve terminal C or D (harness-side) and main relay terminal C (harness-side) 

Short circuit 

-

If there is continuity, the circuit is shorted. Repair or replace the harness.
-

EGR valve terminal E (harness-side) and GND

-

EGR valve terminal A (harness-side) and GND

-

EGR valve terminal B (harness-side) and GND

-

EGR valve terminal F (harness-side) and GND

-

EGR valve terminal C or D (harness-side) and power supply

3. Remove the EGR valve, and inspect for any damage or clogging. 

-

If there is no damage or no clogging, replace the EGR valve.