6 V6-3.7L (2009)
-
If not as specified, replace the OCV.
NOTE:
-
When applying battery positive voltage between the OCV terminals, the connection can be either of the following:
-
Positive battery cable to terminal A, Negative battery cable to terminal B
-
Positive battery cable to terminal B, Negative battery cable to terminal A
6. Stop applying battery positive voltage and verify that the spool valve returns to the maximum valve timing retard position.
-
If not as specified, replace the OCV. See: Service and Repair
7. Install in the reverse order of removal.