mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Campaign MSP18 - A/C Blower Relay Terminals|Page 224 > < Radiator Cooling Fan Control Module Relay|Locations
Page 1
background image

Technical Service Bulletin # 0700508

Date: 080815

Campaign MSP18 - A/C Blower Relay Terminals

Bulletin No.: 07-005/08

Last Issued: 08/15/2008

Subject:
MAZDA SERVICE PROGRAM (MSP18) - HVAC BLOWER MOTOR RELAY TERMINAL INSPECTION

APPLICABLE MODEL(S)/VINS
2009 MAZDA6 vehicles built on or before August 8, 2008.

DESCRIPTION

Some vehicles may have blower motor relay terminals that are not locked in place and may cause a thermal deformation to the fuse box housing.

NOTE:

^

UNDER THE MAZDA SERVICE PROGRAM (MSP18), ALL CURRENT DEALER INVENTORY AND RETAILED VEHICLES FOUND
TO BE PRODUCED ON OR BEFORE AUG. 8, 2008, MUST BE INSPECTED AND REPAIRED ACCORDING TO THE INSTRUCTIONS
CONTAINED IN THIS SERVICE BULLETIN.

^

BEFORE PERFORMING ANY REPAIR, VALIDATE THAT THE VEHICLE IS APPLICABLE TO THIS PROGRAM BY PERFORMING
AN "eMDCS WARRANTY VEHICLE INQUIRY" AND VERIFYING THE VEHICLE DISPLAYS CAMPAIGN "MSP18" AND ITS
CAMPAIGN STATUS DISPLAYS "OPEN". SEE "VEHICLE INSPECTION PROCEDURE" BELOW.

DEALER INVENTORY:

Inspect and repair all applicable vehicles currently in dealer inventory according to the procedures contained in this service bulletin.

RETAIL VEHICLES:

When an applicable retail vehicle is brought into the dealer for any type of repair or scheduled maintenance, perform an eMDCS Warranty Vehicle
Inspection and check the status of MSP18. If status of MSP18 is "OPEN" inspect and repair if necessary, the vehicle according to the procedures
contained in this service bulletin.

VEHICLE INSPECTION PROCEDURE

1.

Verify 2009 Mazda6 vehicle was built on or before August 8, 2008:

-

If the vehicle was not built on or before August 8, 2008, return the vehicle to the customer or inventory.

-

If the vehicle was built on or before August 8, 2008, proceed to Step 2.