Evaporator Temperature Sensor / Switch: Testing and Inspection
Evaporator Temperature Sensor Inspection [Manual Air Conditioner]

EVAPORATOR TEMPERATURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]

1. Set the fan speed MAX HI.

2. Set the temperature control at MAX COLD (Turn the left).

3. Turn the A/C switch off.

4. Set the RECIRCULATE mode.

5. Close all doors and windows.

6. Wait for 5 min.

7. Remove the glove compartment.  See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair

8. Disconnect the evaporator temperature sensor connector.  See: Service and Repair/Evaporator Temperature Sensor Removal/Installation [Manual Air
Conditioner]

9. Measure the temperature at the blower inlet.

10. Measure the resistance between terminals of the evaporator temperature sensor. 

-

If the resistance is not as shown in the graph, replace the evaporator temperature sensor.

Refrigerant Pressure Sensor / Switch, HVAC > < Evaporator Temperature Sensor Inspection [Full-Auto Air Conditioner]