Control Module: Component Tests and General Diagnostics

TCM Inspection [AW6A-EL]

TCM INSPECTION [AW6A-EL]

TR Switch Inspection

1. Verify that the starter operates only when the ignition is switched to the START with the selector lever in P or N position.

2. Verify that the back-up lights illuminate when shifted to R position with the ignition at ON.

3. Verify that the positions of the selector lever and the selector indicator light correspond. 

-

If there is any malfunction, perform the "Neutral Position Learning".  See: Service and Repair/TCM Removal/Installation [AW6A-EL]

Control Module Inspection

WARNING:

-

Be careful not to damage the connector waterproofing when measuring the TCM terminal voltage. If damaged, the waterproofing efficiency could
be negatively affected.

NOTE:

-

Use the ground of terminal A9 of the TCM connector (wiring harness-side) when measuring terminal voltage, as an error may occur when
connecting the negative circuit tester to ground.

1. Remove the air cleaner component.  See: Engine, Cooling and Exhaust/Engine/Intake Manifold/Service and Repair

2. Measure the voltage at each TCM connector (wiring harness-side) terminal and refer to the terminal voltage table. 

-

If the voltage is not as specified in the Terminal Voltage Table (Reference), inspect the parts under "Inspection item (s)".

Terminal Voltage Table (Reference)

Component Tests and General Diagnostics|Page 3477 > < Automatic Transaxle Location Index [FS5A-EL]|Page 3474