mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

A/C - Decreased Cooling, Low Air Flow from Vents|Page 2803 > < A/C Evaporator - Freezes Up|Page 2798
Page 1
background image

Ambient Temperature Sensor / Switch HVAC: All Technical Service Bulletins
A/C - Decreased Cooling, Low Air Flow from Vents

Category     

Applicable  Model/s               

Subject

Bulletin No. 021/87

16

1986-1987 626

A/C FREEZE-UP

Issued

10/1/87

Revised

DESCRIPTION

When a customer complains of the following items, the vehicle is probably experiencing A/C evaporator icing or freeze up.

1.

Decrease in air flow from the A/C vents after a short period of time.

2.

A/C cools well only for the first few minutes of operation. (Depending on the weather condition, it may take 30-60 minutes to freeze up.)

To confirm a customer complaint, dealers are requested to make sure that the compressor does not cycle after a short period of time.

To correct this, the thermistor probe should be replaced with the thermostat.

NOTE:
If the compressor does cycle and there is insufficient cooling, the heater mixture door could be partially open. Check and adjust it in accordance with
Service Bulletin Category 16, 022/87.

PARTS INFORMATION

To replace the thermistor with the thermostat, the following parts are necessary.