mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

All Technical Service Bulletins for Evaporator Core:|1604589 > < A/C Evaporator - Freezes Up
Page 2
background image

2.

Check if thermistor probe is properly installed in evaporator.

NOTE:
If the tip of thermistor (red epoxy) is cracked or brittle, replace thermistor with thermistor explained in Step 3.

If the thermistor is properly installed and the conditions in Step 1 continue to occur, replace thermistor with one which contains a white mark
or black line on the label as shown.
CAUTION:
When replacing the thermistor, be sure to install the new one to correct position per specifications as shown in Step 2.

NOTE:
White mark or black line indicates thermistor has passed critical testing at manufacturer. Also, thermistor part number (0000 67 0957 85) has
NOT been changed.

WARRANTY INFORMATION

Customer Comment Code:

A1

Damage Code:

AB

Part No. of Main Cause:

0000 67 0957 85

Operation No:

U0604X-R-X (Evaporator R&R) U0003X-R-X (Evacuation Charge)

Labor Hour:

0.5 (Evaporator R&R) 0.5 (Evacuation Charge)

All Technical Service Bulletins for Evaporator Core:|1604589 > < A/C Evaporator - Freezes Up