Symptom: Airflow mode does not change
Related components Airflow mode actuator, heater control unit wiring harness.
Airflow mode actuator
The airflow mode actuator opens and closes the airflow mode doors by means of heater control signals and the link rod. It is equipped with sliding
contacts to set the stopping position.
Step 1
1. Disconnect the airflow mode actuator connector.
2. Connect battery positive voltage to the terminals I and J of the airflow mode actuator, and check the actuator operation.
3. If not as specified, replace the airflow mode actuator.
4. If correct, go to Step 2.