mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

A/C - Intermittent Operation|Page 6650 > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 6641
Page 1
background image

Refrigerant Temperature Sensor: All Technical Service Bulletins
A/C - Intermittent Operation

Bulletin No.: 006/96
Issued: 09/09/96
Revised:

Category

U

Applicable Model/s
See Below

Subject:
INTERMITTENT A/C OPERATION

AFFECTED MODELS
All 1993 - 96 626/MX-6

All 1992-95 929

All 1992 - 94 Protege

All 1992 - 95 MX-3

All 1995 - 96 Millenia

DESCRIPTION

The A/C compressor may stop operating. Intermittent operation may also occur when directly applying battery voltage during testing. This concern may
be caused by a damaged thermal protector.

Customers complaining of this concern should have the thermal protector tested according to the instructions in this bulletin.

NOTE:

Ensure that the following diagnostics are performed prior to compressor replacement.

INSPECTION PROCEDURE

1.

Check the battery voltage at the thermal protector terminal when the compressor stops working, (with A/C Switch and Blower Fan Switch ON).

^

If voltage is present proceed to step 2.

^

If voltage is not present check the power source from the battery to the thermal protector (Wiring harness, A/C Switch, A/C Relay, sensors)
according to the workshop manual or BETM.

A/C - Intermittent Operation|Page 6650 > < Refrigerant Pressure Sensor / Switch, HVAC|Testing and Inspection|Page 6641