626 V6-2496cc 2.5L DOHC (1995)
Refrigerant Temperature Sensor: Customer Interest
A/C - Intermittent Operation
Bulletin No.: 006/96
Issued: 09/09/96
Revised:
Category
U
Applicable Model/s
See Below
Subject:
INTERMITTENT A/C OPERATION
AFFECTED MODELS
All 1993 - 96 626/MX-6
All 1992-95 929
All 1992 - 94 Protege
All 1992 - 95 MX-3
All 1995 - 96 Millenia
DESCRIPTION
The A/C compressor may stop operating. Intermittent operation may also occur when directly applying battery voltage during testing. This concern may
be caused by a damaged thermal protector.
Customers complaining of this concern should have the thermal protector tested according to the instructions in this bulletin.
NOTE:
Ensure that the following diagnostics are performed prior to compressor replacement.
INSPECTION PROCEDURE
1.
Check the battery voltage at the thermal protector terminal when the compressor stops working, (with A/C Switch and Blower Fan Switch ON).
^
If voltage is present proceed to step 2.
^
If voltage is not present check the power source from the battery to the thermal protector (Wiring harness, A/C Switch, A/C Relay, sensors)
according to the workshop manual or BETM.