626 ES V6-2.5L DOHC (1997)
Reference
Step 8
1. Check for continuity between the terminals of the hazard warning switch.
2. If correct, reconnect the connector and go to Step 9.
3. If not as specified, replace the hazard warning switch.
Ohmmeter Connection
Reference
Step 9
1. Turn the hazard warning switch on.
2. Check for continuity between terminal C (G/R) of the flasher unit connector and ground.
Step 10
1. Reconnect the connector and turn the ignition switch to ON.
2. Set the turn switch to the right position and measure the voltage at terminal G (G/W) of the flasher unit connector.