626 ES V6-2.5L DOHC (1997)
Voltmeter Connection
Action Chart
Step 5
Set the turn switch to the left position and measure the voltage at terminal F (G/Y) of the flasher unit connector.
Pinpoint Test 3
Flowchart No.3 Symptom hazard light function does not operate (turn signal function operates)
Possible Cause
^
Damaged hazard warning switch
^
Damaged flasher unit
^
Open or short circuit in wiring harness Poor connection of connector
Ohmmeter Connection
Ohmmeter Connection
Action Chart