Shift Indicator: Adjustments

Indicator Panel Adjustment 

1. Loosen the indicator panel screws.
2. Shift the selector lever to P position.

3. Align the alignment screws in the slider with the holes in the indicator panel. Install heavy-gauge wire to hold the slider.

4. Tighten the indicator panel screws in the order shown in the figure.

Tightening torque 2.0 - 2.9 Nm (20 - 30 kgf-cm, 18 - 26 inch lbs.) 

5. Remove the heavy gauge wire.
6. Verify that the selector lever properly aligns with the indicator in each range.