mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Inspection of Output Voltage|Page 1676 > < Inspection of Output Voltage|Page 1674
Page 2
background image

6. Rotate the throttle link by hand and adjust the PCM terminal 89 voltage to specification.
7. Tighten the attaching screws.

Tightening Torque: 
1.6 - 2.3 Nm {16 - 24 kg.cm, 14 - 21 in.lb.} 

8. When the throttle valve is at the wide open throttle, verify that the PCM terminal 89 voltage is in the specification.

-

If not as specified, check related wiring harness. 

-

If they are okay, replace the throttle body.

USING THE NGS TESTER

Check in the following order:

1. Connect the SSTs (NGS tester) to the data link connector.
2. Verify that the throttle valve is at the closed throttle position.
3. Turn the ignition switch to ON.
4. Select the " PID/DATA MONITOR AND RECORD" function on the NGS tester display and press TRIGGER.

5. Select "TP V" on the NGS tester display and press START. The NGS tester measures and shows the voltage.
6. Tighten the attaching screws.

Tightening Torque:  
1.6 - 2.3 Nm {16 - 24 kg.cm, 14 - 21 in.lb.} 

Inspection of Output Voltage|Page 1676 > < Inspection of Output Voltage|Page 1674