626 LX V6-2.5L DOHC (1997)
Backup Lamp Switch: Testing and Inspection
Inspection MTX
1. Disconnect the back-up light switch connector.
2. Shift the shift lever to the reverse position.
3. Check for continuity between terminals A and B of the back-up light switch.
4. If there is no continuity, replace the back-up light switch.