mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Compressor Control (A/C Relay Signal) Inspection|Page 914 > < Compressor Control (A/C Relay Signal) Inspection|Page 912
Page 3
background image

4.  If the compressor does not operate, go to Step 6.

Step 6

1.  Disconnect the refrigerant pressure switch connector.

2.  Connect a jumper wire between terminals of the connector as shown.
3.  Turn the ignition switch ON and press the AUTO switch ON.
4.  Set the temperature at 18°C (64°F}.
5.  If the compressor operates, measure the refrigerant pressure. 

If the pressure is normal, replace the refrigerant pressure switch.

6.  If the compressor does not operate, go to Step 7.

Step 7

Refrigerant pressure switch connector voltage inspection
1.  Disconnect the refrigerant pressure switch connector.
2.  Turn the ignition switch ON, and turn the AUTO switch ON.
3.  Set the temperature at 18°C (64°F}.

4.  Measure voltage at terminal wire (LG) of the connector.

Step 8

Magnetic clutch terminal voltage inspection
1.  Turn the ignition switch ON, and turn the AUTO switch ON.
2.  Set the temperature at 18°C (64°F).

Compressor Control (A/C Relay Signal) Inspection|Page 914 > < Compressor Control (A/C Relay Signal) Inspection|Page 912