929 V6-3.0L SOHC (1989)
Oxygen Sensor: Service and Repair
1.
Disconnect the connector.
2.
Remove the oxygen sensor and gasket.
3.
Install the oxygen sensor and a new gasket, tightening to 29-49 Nm (3-5 m-kg, 22-36 ft. lbs.)
Oxygen Sensor: Service and Repair
1.
Disconnect the connector.
2.
Remove the oxygen sensor and gasket.
3.
Install the oxygen sensor and a new gasket, tightening to 29-49 Nm (3-5 m-kg, 22-36 ft. lbs.)