929 V6-3.0L SOHC (1989)
Starter Motor: Testing and Inspection
No-Load Test
Fig. 6 No-load Test Connections
1.
After adjusting pinion gap, form a test circuit as in Fig. 6 using a voltmeter and an ammeter. Use heavy gauge wire and tighten terminals fully.
2.
Close switch K to run starter, voltage and ammeter readings, refer to Starting and Charging/Starting System/Specifications for specifications.