B2300 L4-2.3L (2008)
Air Flow Meter/Sensor: Service and Repair
MASS AIR FLOW/INTAKE AIR TEMPERATURE (MAF/IAT) SENSOR REMOVAL / INSTALLATION
CAUTION: Sensing elements located in the air flow bypass are not to be tampered with.
1. Disconnect negative battery cable.
2. Disconnect the mass air flow (MAF) sensor electrical connector.
3. Disconnect the air cleaner outlet tube from the MAF sensor.
4. Remove the four bolts and the MAF sensor.