mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3872 > < Initial Inspection and Diagnostic Overview|Page 3870
Page 40
background image

The scan tool communicates with the ISO 9141 network through the data link connector (DLC). The generic electronic module (GEM) communicates
with the scan tool through the ISO 9141 communications network, circuit (GY).

Possible Causes

Circuit (GY) open, short to ground or short to voltage

-

DLC D-01

-

GEM

CAUTION:  Use the correct probe adaptor(s) when making measurements. Failure to use the correct probe adaptor(s) may damage the
connector.

Pinpoint Test 8: No Module/Network Communication - No Power to the Diagnostic Tool

PINPOINT TEST 8: NO MODULE/NETWORK COMMUNICATION - NO POWER TO THE DIAGNOSTIC TOOL

Step 1-Step 3

Normal Operation

The scan tool is connected to the data link connector (DLC) to communicate with the high speed controller area network (HS-CAN) and International
Standards Organization (ISO) 9141 communications networks.

Possible Causes

-

Fuse

-

Circuit (GY/R) open

-

Circuit (B/W) open circuit

-

Circuit (B/Y) open

-

DLC D-01

-

Scan tool

Initial Inspection and Diagnostic Overview|Page 3872 > < Initial Inspection and Diagnostic Overview|Page 3870