mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Daytime Running Lamp|Testing and Inspection > < Diagram Information and Instructions|Page 4508
Page 1
background image

Daytime Running Lamp: Description and Operation

DAYTIME RUNNING LAMPS (DRL)

NOTE:   The smart junction box (SJB) must be configured when installing a new module.

The DRL system operates the low-beam headlamps at a reduced intensity. The SJB supplies pulse width modulated (PWM) voltage to the low-beam
headlamps when the following conditions are met.

-

The high beam headlamps are not on.

-

The ignition switch is in the RUN position.

-

The parking brake control is released.

The DRL system utilizes the existing circuitry in the vehicle.

Principles of Operation

NOTE:  When installing a new smart junction box (SJB), it must be configured for this feature, if originally equipped.

The daytime running lamps (DRL) are controlled by the SJB. The SJB operates the low beam headlamps at a reduced intensity. The DRL driver (integral
to the SJB) supplies pulse-width modulated (PWM) voltage to the low beam head lamps when the following conditions are met.

-

The high beam head lamps are not on.

-

The ignition switch is in the RUN position.

-

The parking brake is not engaged.

The SJB utilizes a protective circuit strategy for many of its outputs (for example, the headlamp output circuit). Output loads (current level) are
monitored for excessive current (typically short circuits) and are shutdown (turns off the voltage or ground provided by the module) when a fault is
detected. A continuous trouble code (DTC) is stored at that time for the fault. The circuit will then reset after an ignition cycle or customer demand of the
function (switching the component on, 5-minute battery saver being energized). When an excessive circuit load occurs several times, the module shuts
down the output until a service procedure is performed. At the same time, the continuous DTC that was stored on the first failure will not clear by a
command to clear the continuous DTCs. The module will not allow this code to be cleared or the circuit restored to normal until a successful on-demand
self-test proves that the fault has been repaired. After the on-demand self-test has successfully completed (no on-demand DTCs present), the continuous
DTC will have been cleared and the circuit function will return.