B3000 V6-3.0L (2007)
4. Remove the four bolts and the MAF sensor.
CAUTION: Do not tamper with the MAF sensing elements located in the airflow bypass. Tampering may result in failure.
NOTE: The MAF sensor module and body are calibrated and installed as a unit.
5. To install, reverse the removal procedure.
Tightening torque: 4-5 N.m {41-51 kgf-cm, 38-44 in-lbf}