B3000 DS Cab Plus 2WD V6-3.0L OHV (2001)
Air Door Actuator / Motor: Service and Repair
Blend Door Actuator
BLEND DOOR ACTUATOR REMOVAL/INSTALLATION
1. Rotate the temperature control knob to the full COOL position.
2. Remove the passenger air bag module.
3. If equipped with anti-theft/keyless entry, remove the screws and position aside the anti-theft/keyless en- try module.
4. Detach and position aside the electrical connector.
5. Detach and position aside the RH demister hose.
6. Release the two clips and detach the temperature blend door control cable.