B3000 SE Cab Plus 4 2WD V6-3.0L OHV (2001)
3.
Remove the black (negative) and red (positive) connectors from the fuel pump.
4.
Cut the black and red wires to the fuel pump 3 inches (76 mm) below the flange of the fuel pump.
5.
Solder both the red and black wires of the RFI Filter to the red and black wires below the flange. Use heat shrink tubing over the solder
connectors.
NOTE:
Heat shrink tubing must be used over all solder connections; covering the entire soldered area to prevent exposure.
WARNING:
All soldering and heat shrinking steps should be performed AWAY from the fuel tank area.
6.
Connect the RFI filter connectors to the spade terminals on the fuel pump.