mazda Workshop Repair Guides

Mazda Workshop Service and Repair Manuals

Valve Cover|Service and Repair|Page 1131 > < Customer Safety Information|Page 1127
Page 1
background image

Valve Cover: Service and Repair

VALVE COVER-RH REMOVAL/INSTALLATION

1. Disconnect the negative battery cable. 

2. Disconnect the ignition coil connector.
3. Disconnect the spark plug wires from the RH spark plugs and position aside.
4. Disconnect the Intake Air Temperature (IAT) sensor connector.

5. Disconnect the Mass Airflow (MAF) sensor connector and position engine harness aside.

6. Disconnect the vacuum line.

7. Remove the ignition coil bracket.

Valve Cover|Service and Repair|Page 1131 > < Customer Safety Information|Page 1127